网责任编辑: 作者: 人气: - 发表时间:2019-11-24 10:26:00【 Article Source: Original Network Editor: Author: Popularity: - Published: 2019-11-24 10:26:00 [ Tai Zhong small ]
   Known conditions: 5000L fuel tank, independent oil pump circulation system of air cooler, 125L / min, requires 1 hour to drop from 95 ℃ to 60 ℃.
   Heating power Pv calculation
   Pv = ρxV × Cx △ T / H
   = 0.88x5000x2.15x (95-60) /60x60=91.972kw
   Assuming the maximum ambient temperature is 40 ° C,
   The actual temperature difference is:
   T1 ~ T2 = 95-40 = 55 ℃
   Equivalent cooling power of air cooler
   P1 = Pv / (T1-T2)
   = 91.972 / 55 = 1.67kw / ℃
   Select 10% safety margin
   Then P1 = 1.67x1.1 = 1.84kw / ℃
   Selection: When the circulating oil pump is 125L / min, according to the heat dissipation curve, the maximum equivalent cooling power of our standard product is 1.4kw / ℃, <1.84kw / ℃,
   non-compliant.
   Can be customized according to this requirement. 产品。 He Yida custom-made as standard explosion-proof air cooler products.
   If you do not order non-standard products, you can choose two standard AH2490T in parallel, each of which is equipped with a 120L / min circulating pump, which is the most ideal.
   The equivalent cooling power of AH2490T is 1.06kw / ℃, two units: 2x1.06 = 2.12> 1.84kw / ℃, which meets the requirements.
   Conclusion: Two AH2490T air coolers are selected, each equipped with Shanghai Guorui 120L / min circulating pump unit.